Rooftop Unit Installation & Replacement
Commercial RTU installation and replacement planned around your building, equipment requirements and project scope.
The Trane Foundation® 15 Ton Gas/Electric Rooftop Unit is designed for commercial rooftop replacement applications. It features electric cooling, gas heating, R-454B refrigerant, 460V three-phase electrical supply and the Symbio® 700 controller.
| Attribute | Details |
|---|---|
| Brand | Trane |
| Series | Foundation® |
| Model Family | GDK180 |
| Complete Model Number | Needs Configuration Confirmation |
| Nominal Capacity | 15 Tons |
| Unit Type | Gas/Electric Packaged Rooftop Unit |
| Efficiency | Standard |
| Refrigerant | R-454B |
| Voltage | 460V |
| Phase | 3 Phase |
| Frequency | 60Hz |
| Controller | Symbio® 700 |
| Compressor | Scroll |
| Airflow | Convertible – Horizontal or Vertical |
| Heating | Gas |
| Cooling | Electric |
| Attribute | Details |
|---|---|
| Parts Warranty | 1-Year Limited Parts Warranty |
| Compressor Warranty | 5-Year Limited Compressor Warranty |
| Aluminized Heat Exchanger | 5-Year Limited Warranty |
| Stainless Steel Heat Exchanger | 10-Year Limited Warranty |
| Warranty Assistance | Jimmy HVAC assists with manufacturer warranty registration and support |
The Trane Foundation® 15 Ton Gas/Electric Rooftop Unit is a commercial packaged HVAC system designed for larger rooftop replacement applications. It combines electric cooling and gas heating in one integrated rooftop unit.
This configuration belongs to the GDK180 model family and is designed for 460V, three-phase electrical service. It uses R-454B refrigerant and includes Trane’s Symbio® 700 controller for commercial rooftop system operation.
The Symbio® 700 is a factory-installed and programmed controller for Foundation rooftop units in the 15–25 ton range. It supports conventional thermostat control, enhanced thermostat control, constant-volume zone temperature control and variable-volume zone temperature control, depending on the selected equipment configuration.
The controller provides onboard system information and diagnostic capabilities, with access to the Symbio Service and Installation mobile app.
The Foundation series is designed to support commercial rooftop replacement projects. Convertible airflow allows field configuration between horizontal and vertical airflow arrangements. Single-side service access and service-friendly panels support equipment maintenance.
Trane’s published Foundation warranty information includes a 1-year limited parts warranty and a 5-year limited compressor warranty. The product literature specifies a 5-year limited warranty for an aluminized heat exchanger and a 10-year limited warranty for a stainless steel heat exchanger, subject to the selected configuration and applicable terms.
Jimmy HVAC will assist customers with manufacturer warranty registration and warranty-related support. Warranty coverage is subject to Trane’s official terms, registration requirements and eligibility conditions.
Tell us about your commercial rooftop unit, service needs or project. Our team will help you plan the right next step.
Tell us about your rooftop unit and property. We’ll help you discuss the right service or replacement options.
Support for rooftop unit installation, replacement, repairs and maintenance.
Jimmy HVAC provides commercial rooftop HVAC installation, RTU replacement, repair and preventive maintenance for businesses, property managers and commercial properties across Toronto and major GTA communities.
From offices and retail spaces to warehouses, industrial facilities and multi-unit properties, we support commercial rooftop units (RTUs) that provide dependable building heating and cooling.
Need rooftop unit installation, repair, replacement or maintenance? Share your property location, equipment details and project requirements so our team can confirm service availability.
From assessing your rooftop unit to installation and ongoing service, we help you plan your commercial HVAC requirements.
Review your existing rooftop unit, building requirements and heating and cooling needs.
Discuss suitable rooftop HVAC options based on your equipment, property and project scope.
Plan and complete rooftop unit installation or replacement according to project requirements.
Get continued support for rooftop HVAC maintenance, repairs and future service needs.
From rooftop unit installation and replacement to repairs and maintenance, Jimmy HVAC helps businesses manage their commercial heating and cooling requirements.
Commercial RTU installation and replacement planned around your building, equipment requirements and project scope.
Troubleshooting and repair support for rooftop HVAC equipment to address performance issues and system breakdowns.
Routine rooftop unit inspections and maintenance to help identify issues and support reliable system operation.
Support for rooftop heating, air conditioning and ventilation requirements across different commercial properties.
Planning a rooftop HVAC project? Tell us about your building, existing equipment and service requirements.
Request a Commercial Quote →Get clear answers about rooftop unit installation, repair, replacement, maintenance, project planning and service for commercial properties across Toronto and the GTA.
Reviews