Rooftop Unit Installation & Replacement
Commercial RTU installation and replacement planned around your building, equipment requirements and project scope.
| Attribute | Details |
|---|---|
| Brand | Carrier |
| Series | WeatherMaster 48QE |
| Model | 48QERM05A2A3-3A0A0 |
| Product Type | Packaged Hybrid Heat Rooftop Unit |
| Cooling Capacity | 4 Tons |
| Net Cooling Capacity | 47,000 BTU/h |
| Cooling Efficiency | 15.3 SEER2 |
| EER2 | 11.8 |
| Gas Heating Input | 90,000 BTU/h |
| Gas Heating Output | Approximately 73,000 BTU/h |
| Gas Heating Efficiency | 81% AFUE |
| Refrigerant | R-454B Puron Advance |
| Compressor | Scroll, Two-Stage Cooling |
| Indoor Fan | EcoBlue Direct-Drive ECM |
| Heat Exchanger | Stainless Steel |
| Heating Fuel | Natural Gas or LP, subject to approved configuration |
| Voltage | 208/230V |
| Phase | Single Phase |
| Frequency | 60Hz |
| Controls | SystemVu Controller |
| Airflow Configuration | Convertible |
| Attribute | Details |
|---|---|
| Warranty Coverage | Carrier Limited Warranty, subject to applicable terms and conditions. |
| Warranty Assistance | Jimmy HVAC will assist with warranty registration and guide you through the warranty process. |
The Carrier WeatherMaster 48QERM05A2A3-3A0A0 is a 4-ton packaged hybrid heat rooftop HVAC system combining an electric heat pump with supplementary natural gas heating. Designed for light commercial applications, this unit provides year-round heating and cooling in one packaged system.
Featuring 15.3 SEER2 cooling efficiency, two-stage cooling, 90,000 BTU/h gas heating input and R-454B Puron Advance refrigerant, the Carrier WeatherMaster 48QE offers flexible dual-fuel operation. Its standard SystemVu controller manages system operation and supports integration with compatible building controls.
Carrier Hybrid Heat technology combines electric heat-pump heating with supplementary gas heating. The heat pump provides heating during suitable outdoor conditions, while the gas furnace can supplement heat-pump operation or operate independently when outdoor temperatures drop. The system can automatically manage the heating changeover using its controls.
This Carrier packaged rooftop system has a nominal 4-ton cooling capacity and a rated net cooling capacity of 47,000 BTU/h. Its two-stage cooling operation provides additional flexibility in meeting changing cooling demands.
The 48QE 4-ton configuration has a published AHRI cooling efficiency rating of 15.3 SEER2 and 11.8 EER2. These ratings help customers compare the cooling efficiency of packaged rooftop HVAC systems.
The integrated gas heating section provides 90,000 BTU/h of heating input and approximately 73,000 BTU/h of heating output. The stainless-steel heat exchanger and 81% AFUE rating are part of the unit’s gas heating configuration.
Carrier EcoBlue technology uses a vane axial indoor fan with an electronically commutated direct-drive motor. Its beltless design eliminates traditional fan belts, pulleys and shaft bearings, helping simplify maintenance and reduce the number of moving parts.
The standard SystemVu controller provides an intuitive display, operating status information and flexible control options. It supports conventional thermostat connections and building automation integration through compatible communication systems.
This WeatherMaster 48QE model uses R-454B Puron Advance refrigerant, a lower-global-warming-potential refrigerant developed for newer-generation HVAC equipment. The unit includes a factory-installed refrigerant leak detection and dissipation system.
The Carrier WeatherMaster 48QE features a packaged cabinet designed for compatible rooftop installations. Its convertible airflow configuration and full-perimeter base rail with rigging adapters and forklift slots support equipment handling and installation.
Carrier provides limited warranty coverage for eligible WeatherMaster 48QE equipment, including specified coverage for the stainless-steel heat exchanger, compressor, SystemVu controller and other parts.
Jimmy HVAC will assist you with warranty registration and guide you through the warranty process. Our team will help you understand the applicable coverage and registration requirements.
Tell us about your commercial rooftop unit, service needs or project. Our team will help you plan the right next step.
Tell us about your rooftop unit and property. We’ll help you discuss the right service or replacement options.
Support for rooftop unit installation, replacement, repairs and maintenance.
Jimmy HVAC provides commercial rooftop HVAC installation, RTU replacement, repair and preventive maintenance for businesses, property managers and commercial properties across Toronto and major GTA communities.
From offices and retail spaces to warehouses, industrial facilities and multi-unit properties, we support commercial rooftop units (RTUs) that provide dependable building heating and cooling.
Need rooftop unit installation, repair, replacement or maintenance? Share your property location, equipment details and project requirements so our team can confirm service availability.
From assessing your rooftop unit to installation and ongoing service, we help you plan your commercial HVAC requirements.
Review your existing rooftop unit, building requirements and heating and cooling needs.
Discuss suitable rooftop HVAC options based on your equipment, property and project scope.
Plan and complete rooftop unit installation or replacement according to project requirements.
Get continued support for rooftop HVAC maintenance, repairs and future service needs.
From rooftop unit installation and replacement to repairs and maintenance, Jimmy HVAC helps businesses manage their commercial heating and cooling requirements.
Commercial RTU installation and replacement planned around your building, equipment requirements and project scope.
Troubleshooting and repair support for rooftop HVAC equipment to address performance issues and system breakdowns.
Routine rooftop unit inspections and maintenance to help identify issues and support reliable system operation.
Support for rooftop heating, air conditioning and ventilation requirements across different commercial properties.
Planning a rooftop HVAC project? Tell us about your building, existing equipment and service requirements.
Request a Commercial Quote →Get clear answers about rooftop unit installation, repair, replacement, maintenance, project planning and service for commercial properties across Toronto and the GTA.
Reviews