Rooftop Unit Installation & Replacement
Commercial RTU installation and replacement planned around your building, equipment requirements and project scope.
| Attribute | Details |
|---|---|
| Brand | Carrier |
| Series | Comfort 14 – 48NL |
| Model | 48NL-B360903 |
| Product Type | Packaged Gas Furnace & Electric Air Conditioner |
| Cooling Capacity | 3 Tons / 36,000 BTU/h |
| Cooling Efficiency | 13.4 SEER2 |
| EER2 | 11 |
| Heating Input | 90,000 BTU/h |
| Heating Output | Approximately 74,000 BTU/h |
| Heating Efficiency | 81% AFUE |
| Refrigerant | R-454B Puron Advance |
| Compressor | Single-Stage |
| Gas Valve | Single-Stage |
| Blower Motor | Multi-Speed |
| Fuel Type | Natural Gas |
| Voltage | 208/230V |
| Phase | Single Phase |
| Frequency | 60Hz |
| Airflow Configuration | Convertible |
| Attribute | Details |
|---|---|
| Warranty Coverage | As per Carrier’s applicable limited warranty terms. |
| Warranty Assistance | Jimmy HVAC will assist with warranty registration and guide you through the warranty process. |
The Carrier Comfort 14 48NL-B360903 is a 3-ton packaged heating and cooling system that combines natural gas heating and electric air conditioning in one compact unit. Designed for compatible residential applications, this Carrier packaged gas/electric system provides 36,000 BTU/h of nominal cooling capacity and 90,000 BTU/h of nominal gas heating input.
With 13.4 SEER2 cooling efficiency, 11 EER2 and 81% AFUE heating efficiency, the Carrier Comfort 14 offers a practical combination of heating and cooling performance. It uses R-454B Puron Advance refrigerant and operates on a 208/230V single-phase electrical supply.
This Carrier gas/electric packaged unit combines an air conditioner and gas furnace in one system. It uses natural gas for heating and electricity for cooling, providing year-round temperature control through a single packaged installation.
With 36,000 BTU/h of nominal cooling capacity, this 3-ton packaged air conditioner is designed for applications requiring this cooling capacity. Correct equipment sizing should be determined by a professional load calculation.
The Comfort 14 series provides 13.4 SEER2 cooling efficiency and 11 EER2. These efficiency ratings help customers compare the cooling performance of packaged HVAC systems.
The integrated natural gas furnace has a nominal heating input of 90,000 BTU/h and approximately 74,000 BTU/h of heating output. Its 81% AFUE rating describes the furnace’s annual fuel utilization efficiency.
This model uses Carrier Puron Advance R-454B refrigerant. R-454B is a lower-global-warming-potential refrigerant used in Carrier’s newer-generation air conditioning equipment.
Carrier offers limited warranty coverage for eligible equipment under its applicable warranty terms.
Jimmy HVAC will assist you with warranty registration and guide you through the warranty process. Our team can help you understand the applicable coverage and the steps involved.
Tell us about your commercial rooftop unit, service needs or project. Our team will help you plan the right next step.
Tell us about your rooftop unit and property. We’ll help you discuss the right service or replacement options.
Support for rooftop unit installation, replacement, repairs and maintenance.
Jimmy HVAC provides commercial rooftop HVAC installation, RTU replacement, repair and preventive maintenance for businesses, property managers and commercial properties across Toronto and major GTA communities.
From offices and retail spaces to warehouses, industrial facilities and multi-unit properties, we support commercial rooftop units (RTUs) that provide dependable building heating and cooling.
Need rooftop unit installation, repair, replacement or maintenance? Share your property location, equipment details and project requirements so our team can confirm service availability.
From assessing your rooftop unit to installation and ongoing service, we help you plan your commercial HVAC requirements.
Review your existing rooftop unit, building requirements and heating and cooling needs.
Discuss suitable rooftop HVAC options based on your equipment, property and project scope.
Plan and complete rooftop unit installation or replacement according to project requirements.
Get continued support for rooftop HVAC maintenance, repairs and future service needs.
From rooftop unit installation and replacement to repairs and maintenance, Jimmy HVAC helps businesses manage their commercial heating and cooling requirements.
Commercial RTU installation and replacement planned around your building, equipment requirements and project scope.
Troubleshooting and repair support for rooftop HVAC equipment to address performance issues and system breakdowns.
Routine rooftop unit inspections and maintenance to help identify issues and support reliable system operation.
Support for rooftop heating, air conditioning and ventilation requirements across different commercial properties.
Planning a rooftop HVAC project? Tell us about your building, existing equipment and service requirements.
Request a Commercial Quote →Get clear answers about rooftop unit installation, repair, replacement, maintenance, project planning and service for commercial properties across Toronto and the GTA.
Reviews